Precision Optoelectronic Fire Protection Systems

Flame Detector Supplier & Factory serving Germany

Industrial Flame Detectors for the German Market

Explore our premium optoelectronic flame monitoring systems calibrated to meet Germany's high safety directives, including ATEX compliance and DIN EN ISO guidelines.

Chengdu Factory & Office

Chengdu Factory & Office

Deyang Factory

Deyang Factory

Company Profile

Founded in 2003, Xinhaosi is one of the most influential and trusted brands in the global gas safety industry. Over the past two decades, we have steadily built a robust and comprehensive production and service system, which integrates cutting-edge R&D, intelligent manufacturing with advanced automation equipment, digital marketing across global channels, professional after-sales support with an experienced technician team, flexible OEM/ODM services, as well as CNAS-Accredited laboratory calibration services that meet international standards.

Our diversified product portfolio covers industrial & residential gas detection & alarm systems, industrial & household gas solenoid valves, and urban gas pipeline network monitoring systems—all engineered to adapt to complex working environments and strict safety requirements. We produce and sell tens of millions of units annually, catering to a wide range of industries that demand reliable gas detection solutions, including oil & gas exploration and production, petrochemicals, urban gas distribution, automotive manufacturing, pharmaceuticals, new energy, steel production, and beverage processing.

Guided by the core mission of “Making Gas Safety Accessible Everywhere,” we consistently deliver high-performance, reliable products and customized solutions tailored to each client’s unique needs. Every item we manufacture undergoes rigorous quality control tests, and every service we provide is backed by our professional technical team, fully embodying our unwavering commitment to safeguarding gas safety across both industrial workplaces and residential environments, and striving to build a safer world with sustainable gas safety technologies.

Germany’s Industrial Fire & Flame Safety Landscape

Navigating the complex regulatory and technical demands of the German chemical, hydrogen, automotive, and heavy industries.

Strict Alignment with European Safety Standards

Germany’s industrial sector is renowned globally for its stringent safety regulations, overseen by bodies such as the TÜV, PTB, and guided by the German Social Accident Insurance (DGUV) regulations. For flame detection in high-risk zones, compliance is non-negotiable. Our manufacturing process conforms to the harmonized European Standard EN 54-10 (Fire detection and fire alarm systems - Part 10: Flame detectors - Point detectors), ensuring our devices undergo thorough optoelectronic calibration and response-time testing.

Operating in German Chemical Parks (Chemparks) like Ludwigshafen, Leverkusen, or Marl requires rigorous explosion protection alignment. Our ATEX-certified flame detectors operate safely under ATEX Directive 2014/34/EU guidelines for Zones 1/21 and Zones 2/22, minimizing risk of ignition in environments containing flammable gases, mists, or combustible dusts.

Key German Technical Frameworks Supported:

  • TRBS (Technical Rules for Operational Safety) - Standardizing risk assessment procedures for explosive atmospheres.
  • DIN 14675 - Outlining design, installation, and operation parameters for fire alarm systems within German infrastructures.
  • VdS Guideline compliance - Supporting the high-reliability expectations of German property insurers.
  • CE and SIL-2/SIL-3 functional safety engineering for automated plant shutdown interfaces.

Technical Strength

Adhering to ISO9001 quality management system standards, Xinhaosi's core products have obtained a full range of authoritative certifications, including national compulsory Products Certification, explosion-proof certification, fire product certification, CPA measurement instrument type approval certificate, and international approvals as CE, SIL. Additionally, Xinhaosi holds honors such as "National Quality Integrity Benchmark Enterprise" , "National Quality Leading Enterprise in the Gas Alarm Industry," member of the China Fire Protection Association, and the main drafting organization for the national standard of solenoid valves, further confirming its industry influence and reputation.

In the field of intellectual property, Xinhaosi has built a robust innovation system with over 50 patents and software copyrights . These patents cover core technological areas, including a graphical monitoring system for gas detection and alarm, which enables predictive maintenance based on historical data to reduce equipment failure rates by over 30%, and a solenoid valve with flow monitoring functionality that integrates flow detection and alarm capabilities . The company also pioneered China's first networked bus-type gas leakage monitoring system and the only maximum-point gas leakage monitoring system certified by the Ministry of Public Security, demonstrating its leading position in cutting-edge technological research.

Our in-house laboratory is accredited by the China National Accreditation Service for Conformity Assessment (CNAS), recognized both domestically and internationally under the ILAC-MRA framework. It operates in accordance with ISO/IEC 17025, the international standard for testing and calibration laboratories. It provides reliable and traceable testing services for gas detection and alarm products, solenoid valves, and related safety equipment. Test reports issued by the CNAS-accredited laboratory are widely accepted by regulatory authorities, certification bodies, and customers in China and overseas, helping to ensure product quality, safety compliance, and market access.

Technical Strength Laboratory

Localized Applications in German Industry

Tailored optoelectronic solutions matching the core industrial engines of Germany, from Bavaria to Lower Saxony.

Hydrogen Production & Fueling (H2-Ready)

As Germany transitions towards hydrogen energy (National Hydrogen Strategy), we supply high-speed Single UV and UV/IR dual band detectors optimized for near-invisible hydrogen flames. Highly critical for Electrolyser rooms and fuel-cell facilities.

Automotive & Paint-Spraying Lines

German automotive paint shops (OEMs in Baden-Württemberg and Bavaria) require flame detection systems capable of distinguishing paint solvent fire signatures from robot movement reflection and high arc-welding interference.

Waste-to-Energy (Müllverbrennungsanlagen)

German environmental regulations require thermal recovery. Our IR3 (Triple IR) multi-spectrum sensors monitor waste storage bunkers, operating reliably under thick smoke, dust, and steam atmospheres to identify deep fires.

Global Industrial Safety Insights & Tech Roadmap

Deploying advanced AI algorithms to solve false alarm issues in complex multi-spectral flame detection configurations.

Smart Multi-Spectral Sensor Interlinking

Historically, industrial factories suffered severe losses due to accidental activations of gaseous fire suppression systems triggered by false alarms. Modern flame detection relies on analyzing temporal and spectral characteristics of dynamic fire.

Our technology utilizes triple-infrared optical sensors calibrated to specific absorption peaks: Carbon Dioxide (4.4 µm) alongside ambient reference bands (3.8 µm and 4.7 µm). Our DSP microprocessors apply Fast Fourier Transform (FFT) analysis to cross-check flame flicker profiles (1 to 15 Hz), filtering out hot-body radiation, solar glare, and heavy-duty machinery heat.

  • Zero false alarms from arc-welding operations or halogen lamps.
  • Ultra-fast detection speeds of under 5 seconds for liquid fuel pool fires.
  • RS485 Modbus RTU communication integrated with SIL-2 compliant Relays.
50+
Patents & Copyrights
<3s
Response Velocity
SIL-2
Functional Safety
CNAS
Accredited Lab

Company History & Strategic Evolution

A twenty-year timeline of innovation, engineering compliance, and industrial gas/flame security scaling.

2003-2008: Start Up

● Established on April 17th, 2003.
● Launched the 1st generation of gas leak alarm & fire fighting products.

Start Up Era

2009-2012: Initial Scale Achievement

● Started gas safety valve production.
● Expanding OEM business.
● Moved to the office building in Longtan industrial park.

Scale Expansion

2013-2016: Rapid Growth

● 10 million pcs gas detector sales achieved.
● Moved into Chengdu factory building.
● Completed sales & service network across China.
● Launched the fire power monitoring system products.

Rapid Growth

2017-2020: Leading Up

● Self-developed IoT platform launched.
● Launched fire automatic alarm, emergency lighting, and evacuation systems.
● Obtained high-tech enterprise certificate.
● Qualified official supplier of China’s top 5 gas suppliers.

IoT Era

2021-2023: Steady Development

● Started Deyang factory construction.
● Established the Petrochemical & International business Division.
● Awarded the title of Sichuan Provincial Technology Center.

Internationalization

2024—Future: Embrace the Future

● Deyang factory construction completed and operation started.
● Launched urban gas pipeline network monitoring products.
● Launched wireless detection products.
● Launched AI safety valve products.

Smart AI Future

Advanced Detection & Safety Interfaces

A full portfolio of EN-compliant optical flame sensors, combustible gas sensors, and localized low-voltage control systems serving Germany.

Regulatory Alignment and Traceable Calibration

E-E-A-T Framework: Understanding standard DIN directives and traceability pathways for German distributors.

For German engineers, calibration compliance is key to functional verification under BetrSichV (Industrial Safety Regulation). Our CNAS accredited testing and calibration labs operate under ISO/IEC 17025 guidelines, facilitating mutual recognition under the ILAC-MRA agreement.

This ensures that test reports and safety calibrations issued at our factories are directly traceable, facilitating verification procedures by the German DAkkS (Deutsche Akkreditierungsstelle) and the local fire safety inspectorates.

Whether it is checking spectral sensitivity curves, verifying environmental ingress protection (IP66/IP67), or certifying electromagnetic compatibility (EMC) according to EN 50130-4, every batch leaves with a comprehensive certificate of conformity.

Standard Reference Target Target Area Regulatory Relevance
EN 54-10 Optical Flame Sensors Mandatory for Fire Panel Loop Integration
IEC 61508 Functional Safety SIL 2/3 Safety Instrumental Systems (SIS)
ATEX 2014/34/EU Explosive Atmospheres Required for Zone 1, 2, 21, and 22 Installations

Expert Q&A: Industrial Flame Safety in Germany

Addressing the technical, operational, and regulatory questions critical for engineering bureaus and system integrators.

Q1: What are the differences between Triple IR (IR3) and UV/IR flame detectors in German chemical parks?
Triple IR (IR3) detectors utilize three distinct infrared wavelengths (specifically around the 4.4 micron carbon dioxide emission peak and surrounding reference bands) to recognize fires through dense smoke and water mist without false triggering. A UV/IR detector pairs an ultraviolet phototube with an infrared sensor, requiring simultaneous detection of both UV and IR radiation. UV/IR detectors are faster and suited for hydrogen or clean-gas areas but can be blinded by dense smoke or oil mists, where IR3 models are preferred.
Q2: Are your flame detectors certified under the EN 54-10 standards required by VdS?
Yes, our flame detectors are designed, manufactured, and calibrated in accordance with EN 54-10 (Class 1 performance range). This compliance profile allows seamless integration into industrial fire panel systems (BMA) across Germany. For specific project approvals requiring direct VdS certification stamps, please contact our technical export division.
Q3: How do the detectors handle false alarms from arc welding or solar reflections?
Our sensors integrate proprietary signal processing algorithms that analyze the characteristic modulation frequency of real flame flicker (typically 1 to 15 Hz). Static heat sources, moving vehicles, sunlight reflections, and high-frequency arc welding profiles do not matching this signature, and are filtered out by the digital signal processor (DSP).
Q4: What explosion protection classifications do your detectors offer for Germany?
We provide flame detectors rated up to Ex d IIC T6 Gb and Ex tb IIIC T80°C Db, making them suitable for ATEX Zone 1/21 and Zone 2/22 installations. The robust explosion-proof cast aluminum or stainless steel housings are designed to withstand hazardous atmospheres in oil refineries, paint booths, and chemical storage depots.
Q5: Can these detectors be calibrated locally in Germany to maintain certification?
Our factory provides full calibration certificates traceable under the CNAS / ILAC-MRA framework, which is recognized by Germany's DAkkS. For on-site annual calibration checks required by DIN 14675, our technical team provides specialized flame test lamps that generate correct spectral patterns to verify sensor operations without triggering fire suppression lines.

Partner with an Established Flame Detector Factory

Get in touch with our engineering team for ATEX-compliant, SIL-certified flame detection systems. We provide technical customization, OEM manufacturing options, and full project layout validation services.