Engineered for immediate response in severe environment dynamics. Deployed inside cleanrooms, offshore platforms, and heavy chemical installations in Israel.
Israel's high-tech industrial structure presents a unique intersection of heavy energy systems and highly sensitive, high-value electronics manufacturing. With the expansion of natural gas drilling at the Tamar, Leviathan, and Karish offshore platforms, combined with deep chemical processing clusters in Haifa Bay and dense microelectronics cleanrooms in Silicon Wadi (Kiryat Gat and Yokneam), the demand for robust fire safety engineering has intensified.
System integrators and developers in Israel require Flame Detectors that demonstrate exceptional performance under high ambient temperature, UV radiation, and high humidity. Regulatory compliance forms the absolute baseline—systems must comply with EN 54-10 standards, SIL2/SIL3 functional safety levels, and ATEX/IECEx certifications for explosive atmospheres. The challenge lies in ensuring high sensitivity to hydrocarbon and hydrogen fires while maintaining complete immunity to false alarm sources such as welding, solar flares, and lighting reflections.
In global hazard protection, procurement strategies are undergoing a shift toward vertical integration. International EPC (Engineering, Procurement, and Construction) contractors operating in the Middle East demand not just physical components, but validated safety systems where gas detectors, emergency shutdown solenoid valves, and flame sensors operate under unified communication buses (such as Modbus RTU, HART, or safe loop configurations).
Xinhaosi's China Factory 4.0 Ecosystem meets these requirements by applying automated manufacturing and high-throughput production lines. This process reduces human assembly variance while optimizing material tracing. Every single component—from the optoelectronic photodiode to the explosion-proof cast aluminum enclosure—undergoes strict batch validation in our ISO/IEC 17025 CNAS-Accredited Laboratory. For Israeli procurement officers, this setup translates to a robust supply chain characterized by short lead times, and certified quality standard compliance.
Direct connection to DCS/SCADA via 4-20mA, RS485 Modbus, and dry relay outputs.
Ex d IIC T6 Gb rating guarantees total safety in hydrogen, acetylene, and volatile hydrocarbon environments.
IP66/IP67 rated enclosures prevent moisture ingress in coastal zones like Tel Aviv and Ashdod.
Selecting the optimal optical signature processing technology for target risk environments in Israel.
| Technology Profile | Spectral Sensitivity Range | Optimal Application Case | False Alarm Immunity | Response Profile |
|---|---|---|---|---|
| Triple Infrared (IR3) | Multiple bands in 4.0 - 5.0 µm (focused on CO2 peak) | Hydrocarbon fires, Refineries, Offshore platforms, Fuel depots | Excellent (Rejects arc welding, sunlight, blackbody radiation) | High-speed detection up to 60 meters within 3-5 seconds |
| Dual IR + UV | UV band (185-260 nm) + IR band (4.3-4.5 µm) | Chemical storage rooms, Aerospace testing, Engine test cells | Very High (Cross-checks thermal and ionized gas profiles) | Rapid response to organic, inorganic, and metal fires |
| Single UV | 185 - 260 nm (narrow solar blind band) | Cleanroom semiconductor tool wet-benches, Hydrogen refueling | Moderate (Can trigger on high voltage arcing or lightning) | Ultra-rapid millisecond level response in zero-smoke zones |
| Combustible Gas Integrated | Catalytic & Infrared gas absorption profile | Urban distribution pipelines, Valve regulator stations | High (Specific to gas concentration levels) | Pre-fire preventative detection at LEL limits |
Founded in 2003, Xinhaosi is one of the most influential and trusted brands in the global gas safety industry. Over the past two decades, we have steadily built a robust and comprehensive production and service system, which integrates cutting-edge R&D, intelligent manufacturing with advanced automation equipment, digital marketing across global channels, professional after-sales support with an experienced technician team, flexible OEM/ODM services, as well as CNAS-Accredited laboratory calibration services that meet international standards.
Our diversified product portfolio covers industrial & residential gas detection & alarm systems, industrial & household gas solenoid valves, and urban gas pipeline network monitoring systems—all engineered to adapt to complex working environments and strict safety requirements. We produce and sell tens of millions of units annually, catering to a wide range of industries that demand reliable safety systems, including petrochemicals, new energy, and cleanrooms.
Chengdu HQ & Office
Deyang Automated Factory
Adhering to ISO9001 quality management standards, Xinhaosi's core products have obtained a full range of authoritative certifications, including national compulsory Products Certification, explosion-proof certification, fire product certification, and international approvals such as CE and SIL. We are active members of fire protection associations and key drafting contributors to modern safety valve industrial standards.
In the field of intellectual property, Xinhaosi has built a robust innovation system with over 50 patents and software copyrights. These cover critical technological areas including graphical monitoring systems for gas detection and alarm, which enable predictive maintenance based on historical data to reduce equipment failure rates by over 30%, and solenoid valves with integrated flow monitoring.
Our in-house laboratory is accredited by the China National Accreditation Service for Conformity Assessment (CNAS), recognized both domestically and internationally under the ILAC-MRA framework. It operates in accordance with ISO/IEC 17025, providing reliable, traceable testing reports that ensure product compliance and market access worldwide.
Tracing our evolution from a specialized component vendor to a global safety system manufacturer.
Established on April 17, 2003. Launched our first-generation gas leak detection systems and fire alarm devices.
Initiated gas safety solenoid valve production. Expanded OEM business and relocated to Longtan Industrial Park.
Achieved 10 million units in cumulative sales. Established a nationwide support network and integrated fire power monitors.
Launched our self-developed IoT safety cloud platform. Certified as a national High-Tech Enterprise and secured tier-1 supplier status.
Began construction of the Deyang factory and established our dedicated Petrochemical and International Divisions.
Deyang plant commissioned. Rolled out AI-driven safety valves, wireless detectors, and municipal pipeline monitors.
Real-world hazards engineered for mitigation with Xinhaosi safety technologies.
Deploying Triple IR (IR3) flame detectors around natural gas extraction lines off the Haifa coast. Resists salt-spray, dynamic cloud cover reflections, and monitors long-range hazards.
Integrating Fast UV detectors within Kiryat Gat microelectronics manufacturing tools. Fast-tripping output activates localized inert gas suppression before fire spreads to ventilation ducts.
Installing specialized multi-spectrum UV/IR systems in chemical plants. Detects the characteristic low-radiation signature of hydrogen flame invisible to the human eye, preventing catastrophic secondary explosions.
Addressing key engineering, compliance, and procurement queries for the Israeli and international markets.
Triple IR (IR3) detectors process three distinct bands in the infrared spectrum (typically around 4.3 to 4.5 µm for the primary band and guard bands). This technology distinguishes between hydrocarbon combustion (producing CO2 emissions) and thermal radiation sources like sunlight or warm machinery. UV/IR detectors combine a UV sensor (185–260 nm) with an IR sensor. They offer rapid response to both hydrocarbon and non-hydrocarbon fires (like hydrogen or alcohol) but are generally suited for indoor or sheltered zones, as UV sensors can be sensitive to environmental interference.
Our products are built and certified to international standards such as CE, SIL2, and explosion-proof Ex d. These certifications align with IECEx and European EN 54-10 parameters, which form the technical framework utilized by the Israel Standards Institute (SII) and local fire services for hazardous site approvals. Detailed certification documents and testing reports from our CNAS lab are provided with every batch.
Our patented graphical monitoring system continuously collects performance parameters, including optical signal levels and sensor drift. By tracking performance deviations over time, the system schedules maintenance before a sensor reaches its fault limit, reducing unexpected shutdowns by up to 30%.
Yes. Our flame detectors are housed in corrosion-resistant cast aluminum or heavy stainless steel, sealed to IP66/IP67 ingress ratings. Internal heating modules prevent condensation on the optical window in high-humidity coastal zones, ensuring consistent performance.
Xinhaosi provides comprehensive OEM and ODM support, including customized firmware tuning (such as adjusting fire response speeds or sensitivity profiles), customized enclosure colors, private labeling, and integration of specialized communication protocols (such as Modbus, HART, or localized telemetry systems).
Fully integrated hazard control units, detectors, and automatic shut-off safety valves designed for rugged industrial service.
Bridging field detector matrices with central control SCADA interfaces.
Get in touch with our applications engineering team today to review your project plans, sensor placement mapping, compliance parameters, or request custom quotes.
Consult with an Applications Engineer Now